| Leak Detector WJL-6000
General descriptions: Incorporated with advanced
leak detect technology. WJL-6000 is our new product with the functions
of easy operation, stable function and small appearance; it’s an ideal
and economic halogen leak detector.
Main features: Detects all kinds of halogen refrigerant gas Sensitivity adjusted at any time and it can be adjusted automatically to the best state of detecting Inner precise IC with Ultra-Low power consume circuit design, more stable, longer battery time Double-color visual display of battery voltage Excellent sensor, high sensitivity, longer use time
Applications: The WJL-6000 may also be used to: Detect
leaks in other systems and storage/recovery containers. It will respond
to all halogenated (contains Chlorine of Fluorine) refrigerants.
This includes, but is not limited to: CFCs e.g. R12, R11, R500, R503 etc... HCFCs e.g. R22, R123, R124, R502 etc... HFCs e.g. R134a, R404s, R125 etc... Blends such as AZ-50. HP62. MP39 etc... Detect Ethylene Oxide gas leaks in hospital sterilizing equipment (it will detect the halogenated carrier gas). Detect SF-6 in high voltage circuit breakers. Detect most gases that contain chlorine, fluorine and bromine (halogen gases). Detect cleaning agents used in dry cleaning applications such as per chloroethylene. Detect halogen gases in fire-extinguishing system.
Technical parameters: Operating temperature: 0~52℃ (30℉ to 125℉) Maximum sensitivity: 6 gr/yr, for all halogenated refrigerants Battery life: Approximately 50 hours normal use Response time: Instantaneous Work mode: continuous, no limitation Fixed probe length: 20cm Unit dimensions: 22.9cmx6.5cmx6.5cm Warm-up time: approximately 6 seconds Reset time: two to ten seconds Power supply: 6V DC four cell 7# excellent batteries Catatan : Gambar hanya sebagai ilustrasi, pengiriman barang sesuai stock. Harga tidak terikat, sewaktu - waktu dapat berubah tanpa pemberitahuan terlebih dahulu.
|